Type 1000 |
|
Type 1000 I/P & E/P Transducers |
- Low Cost
- Built-in Volume Booster
- Small Size
- Field Reversible
- Low Air consumption
- Mounts at Any Angle
- Convenient External Span & Zero Adjusts
(Except for Explosion Proof Models)
- Light Weight
- Wide Supply Pressure Range
- Low Supply Pressure Sensitivity
|
|
Product Detail: |
The Type 1000 Transducer is an electro-pneumatic device that reduces a supply pressure to a regulated output pressure directly proportional to an electrical b signal. The Type 1000 accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 BAR) above the maximum output up to 100 psig (6.9 BAR). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM/339 slpm). Model selections include general purpose, NEMA 4X Type, extended range, high relief, intrinsically safe, and explosion proof. |
Part Numbers: |
T-1000 General Purpose ordering inbation: |
Input |
Output* |
Part Number |
Impedance (nominal) |
psig |
BAR |
4-20mA |
3-9 |
0.2-0.6 |
961-072-000 |
90Ω |
9-15 |
0.6-1.0 |
961-073-000 |
90Ω |
3-15 |
0.2-1.0 |
961-070-000 |
180Ω |
3-27 |
0.2-1.9 |
961-074-000 |
220Ω |
6-30 |
0.4-2.1 |
961-075-000 |
220Ω |
1-17 |
0.07-1.2 |
961-116-000 |
250Ω |
3-15 |
0.2-1.0 |
961-089-000 |
180Ω |
10-50mA |
3-15 |
0.2-1.0 |
961-076-000 |
70Ω |
3-27 |
0.2-1.9 |
961-077-000 |
85Ω |
6-30 |
0.4-2.1 |
961-078-000 |
85Ω
============
|
0-5V |
3-15 |
0.2-1.0 |
961-079-000 |
615Ω |
3-27 |
0.2-1.9 |
961-080-000 |
530Ω |
6-30 |
0.4-2.1 |
961-081-000 |
530Ω |
1-9V |
3-15 |
0.2-1.0 |
961-085-000 |
985Ω |
3-27 |
0.2-1.9 |
961-086-000 |
840Ω |
6-30 |
0.4-2.1 |
961-087-000 |
840Ω |
NOTE: For NEMA4X, add 004 suffix. |
T-1000 extended range ordering inbation: |
Input |
Output* |
Part Number |
Impedance (nominal) |
psig |
BAR |
0-60mA |
2-120 |
0.1-8.3 |
961-107-000 |
220Ω |
4-20mA |
3-120 |
0.2-8.3 |
961-111-000 |
260Ω |
2-60 |
0.1-4.1 |
961-117-000 |
225Ω |
0-10V |
3-120 |
0.2-8.3 |
961-112-000 |
805Ω |
0-5V |
2-60 |
0.1-4.1 |
961-118-000 |
500Ω |
T-1000 HIGH RELIEF ordering inbation: |
Input |
Output* |
Part Number |
Impedance (nominal) |
psig |
BAR |
4-20mA |
3-9 |
0.2-0.6 |
961-130-000 |
90Ω |
9-15 |
0.6-1.0 |
961-131-000 |
90Ω |
3-15 |
0.2-1.0 |
961-132-000 |
180Ω |
3-27 |
0.2-1.9 |
961-133-000 |
220Ω |
6-30 |
0.4-2.1 |
961-134-000 |
220Ω |
3-15 |
0.2-1.0 |
961-135-000 |
180Ω |
1-17 |
0.07-1.2 |
961-136-000 |
250Ω |
10-50mA |
3-15 |
0.2-1.0 |
961-137-000 |
70Ω |
3-27 |
0.2-1.9 |
961-138-000 |
85Ω |
6-30 |
0.4-2.1 |
961-139-000 |
85Ω |
* For output pressures less than 3 psi (0.2 BAR) or greater than 30 psi (21 BAR), the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay. Consult Applications Engineers for further inbation. ** NEMA 4 type enclosure option available on all b/output ranges. This option is separate from explosion proof, NEMA 4 units. |
Type 1000 Explosion Proof |
Input |
Output* |
Part Number |
Impedance (nominal) |
Agency Approvals (see notes) |
psig |
BAR |
4-20mA |
3-15 |
0.2-1.0 |
961-098-000 |
180Ω |
Explosion-Proof, Factory Mutual1 |
3-15 |
0.2-1.0 |
961-098-100 |
180Ω |
CSA Explosion Proof |
1-9v |
3-15 |
20-100 |
961-142-000 |
985Ω |
Explosion Proof Factory Mutual1 |
Type 1000 Intrinsically Safe |
4-20mA |
3-15 |
0.2-1.0 |
961-099-000 |
180Ω |
Intrinsically Safe, Factory Mutual3,4 |
3-27 |
0.2-1.9 |
961-100-000 |
220Ω |
Intrinsically Safe, Factory Mutual3,4 |
3-15 |
0.2-1.0 |
961-105-000 |
180Ω |
Intrinsically Safe, CSA5 |
3-27 |
0.2-1.9 |
961-106-000 |
220Ω |
Intrinsically Safe, CSA5 |
6-30 |
0.4-2.1 |
961-101-000 |
220Ω |
Intrinsically Safe, Factory Mutual3,4 |
15-3 |
1.0-0.2 |
961-175-000 |
180Ω |
Intrinsically Safe, Factory Mutual3,4 |
27-3 |
1.9-0.2 |
961-176-000 |
220Ω |
Intrinsically Safe, Factory Mutual3,4 |
30-6 |
2.1-0.4 |
961-177-000 |
220Ω |
Intrinsically Safe, Factory Mutual3,4 |
*For output pressures less than 3 psi or greater than 30 psi the Type 1000 transducer can be coupled to Bellofram Type 75 pneumatic relay. Consult application engineers for further inbation. |
Agency Approval Notes:
- The Type 1000 Explosion-Proof Transducer has been bted, tested and approved by Factory Mutual Research for use in hazardous bs for Class I, Division 1, Group D, Class II, Division 1, Groups E, F & G and Class III requirements. It also has been approved to meet NEMA 4 Outdoor requirements.
- Canadian Standards Association certified for hazardous bs: Class I, Group D, Class II, Groups E, F and G, Class III, CSA Enc. 4.
- Factory Mutual Research Approved as intrinsically Safe for Class I, II, III, Division 1, Groups A, B, C, D, E, G when installed in accordance with interconnection diagram No. 541-000-012 and with the proper energy limiting barriers.
- Factory Mutual Research Approved as nonincendive for Class I, Division 2, Groups A, B, C, D, and suitable for Class II and III, Division 2, Group G. Barriers are not required for nonincendive rating.
- Canadian Standards Association certified as intrinsically safe when connected through certified diode safety barriers in accordance with Bellofram Installation Instruction 541-000-012.
Explosion proof, intrinsically safe, and non-incendive ratings are not affected by recalibrating for split range or reverse acting applications. The Bellofram T-1000 Transducers were tested and found to comply with Electromagnetic compatibility Directive effective January 1, 1996. The relevant EMC specifications tested were the following: EN 50081-1 (1992) and EN 50082-1 (1992). A Technical Construction File, Serial #107 was written and Certificate of Conbity issued by a Competent Body. |
|
Options: |
Option |
Part Number/Last 3 digits |
Explosion Proof Mounting Kit |
971-079-000 |
Explosion Proof Panel Mounting Kit |
971-078-000 |
DIN Rail Kit |
010-115-000 |
Hirschman Connector Kit (3-prong) |
971-126-000 |
Filter Kit, Coalescing, 0.1 micron |
010-140-000 |
Filter Element Kit (for coalescing filter, package of 10) |
010-141-000 |
Output Gauges–Option “8” |
last 3 digits become - 008 |
Dielectric Strength Testing Option “12” |
last 3 digits become - 012 |
NEMA 4X Type Enclosure Option: Option “4” |
last 3 digits become - 004** |
** NEMA 4 type enclosure option available on all b/output ranges. This option is separate from explosion proof, NEMA 4 units. |
|
|
|
|