DP6060-7R3詳細(xì)介紹
DP6060-7R3
1/8 DIN雙輸入過程面板儀表
DP6060 Series
1/8 DIN雙輸入過程面板儀表
模塊化的USB,RS232,RS485串行通信選項(xiàng)和繼電器
數(shù)學(xué)函數(shù):此外,差異,平均,乘法,分,最小,最大,平均,比,濃度,和更多
0到20毫安,4至20毫安,0至5V,1至5V,10V的輸入和±
大型雙線6位數(shù)字顯示,15和12毫米(0.60和0.46)
陽光下可讀的顯示模式
NEMA 4X(IP65)前
通用的85到265 VAC,或12 / 24 VDC輸入功率模型
孤立的24 VDC @ 200馬發(fā)射機(jī)電源
自由軟件的操作,監(jiān)測,和編程
The DP6060 Series process meter combines two independently programmed analog bs with powerful math functions to make an advanced meter capable of handling complex math requirements common in the process industry. Various math functions may be applied to the bs including addition, difference, average, multiplication, division, ratio, and more. A customizable dual-line display allows a wide variety of b variables, math calculations, or units and tags to be displayed based on your application needs. Sunlight readable display models have an extraordinarily bright LED display. The DP6060 has two red LED displays, an upper display 15 mm (0.60") high, and a lower display 12 mm (0.46") high. Each display is a full 6 digits (-99999 to 999999). The displays can be set up to read b channels (A or B), math function channel C, toggle between A & B, B & C, A & C, A & B & C, toggle between channels A, B, or C & units, the max/min of any of the channels, including the math channel (C), set points, gross (without tare) or net (with tare) and gross values of channel A or B, or the Modbus b. No jumpers to set for b selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6060 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly. The DP6060 minimizes the menu selections by auto-detecting the installed options to determine what menu navigation is required.
規(guī)格:
Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display: 15 mm (0.60") high
Lower Display: 12 mm (0.46") high
Display Intensity: 8 intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper and lower displays may be assigned to process values for Channels A (Ch-A), B (Ch-B), or C (Ch-C), toggle between (Ch-A & Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and Ch-A, Ch-B, & Ch-C), toggle between Channel and units, show channel gross value (no tare) or toggle net (tare) and gross values, show relay set points, max and min values, or Modbus b; the second display may also be set to show engineering units or be off, with no display
Front Panel: NEMA 4X (IP65)
Programming Methods: 4 front panel buttons, digital bs, PC and software, Modbus registers, or cloning using copy function
Noise Filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak)/min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital bs; Pass 2: Allows use of function keys, digital bs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital bs
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W maximum, or jumper selectable 12/24 Vdc ±10%, 15 W maximum
Fuse (External, Required): UL recognized, 5 A maximum, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA maximum (standard), (12/24 Vdc powered models rated @ 100 mA maximum); 5 or 10 Vdc @ 50 mA maximum, selectable with internal jumper J4
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV b/output-to-power line; 500 V b-to-output or output-to-P+ supply
Overvoltage Category: Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range: -40 to 65°C
Storage Temperature Range: -40 to 85°C
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adapters
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight: 269 g (9.5 oz)
注釋: Comes complete with 2 side mounting brackets and operator’s manual.
產(chǎn)品型號說明
(1)
DP6060 -
選項(xiàng)描述
(1) Output
選擇
6R0 代表 Dual b process panel meter
6R2 代表 Dual b process panel meter with 2 relays
6R4 代表 Dual b process panel meter with 4 relays
6R5 代表 Dual b process panel meter with 4 to 20 mA output
6R7 代表 Dual b process panel meter with 2 relays and 4 to 20 mA output
7R0 代表 Dual b process panel meter
7R2 代表 Dual b process panel meter with 2 relays
7R3 代表 Dual b process panel meter with 4 to 20 mA
6H0 代表 Dual b process panel meter
6H2 代表 Dual b process panel meter with 2 relays
6H3 代表 Dual b process panel meter with 4 to 20 mA output
7H0 代表 Dual b process panel meter
7H2 代表 Dual b process panel meter with 2 relays
7H3 代表 Dual b process panel meter with 4 to 20 mA output