DP6000-6R4詳細(xì)介紹
DP6000-6R4
1/8 DIN過程面板儀表
DP6000 Series
1/8 DIN過程面板儀表
模塊化的USB,RS232,RS485串行通信選項和繼電器
0到20毫安,4至20毫安,0至5V,1至5V,10V的輸入和±
NEMA 4X(IP65)前
通用的85到265 VAC或12 / 24 VDC輸入功率
大型雙行6-character顯示,15和12毫米(0.60和0.46)
陽光下可讀的顯示模式
孤立的24 VDC @ 200毫安發(fā)射器電源標(biāo)準(zhǔn)
可編程顯示器和功能鍵
32點,平方根,指數(shù)或線性化
的Modbus RTU通信協(xié)議標(biāo)準(zhǔn)?
使用自由軟件,監(jiān)控和編程
The DP6000 Series meter boasts specifications and functionality that bly make it one of the most advanced process meters available. Its dual-line 6-digit display (999,999), advanced signal b conditioning functions, function keys, Modbus RTU serial communications, and optional expansion modules are only a few of the features found on the DP6000. Sunlight readable display models have an extraordinarily bright LED display. They are perfect for applications where the meter is in direct sunlight or in applications where visibility may be impaired by smoke, fog, dust, or distance. The upper display can be programmed to indicate PV, maximum (peak), minimum (valley), alternating maximum/ minimum, one of eight alarm set points, or Modbus b. The lower display can also be configured to display engineering units, set points, user defined legends, or simply turned off. The user friendly dual-line display makes the DP6000 easy to set up and program. No jumpers to set for b selection. All setup and programming are done via the front panel. Three levels of password protection help maintain the reliability of the programming. The Copy feature is used to copy (or clone) all the settings from one DP6000 to other meters in about 20 seconds! The Copy function is a standard feature on all meters. It does not require a communications adaptor, only an optional cable assembly.
General Specifications
Display: Both displays are 6 digits (-99999 to 999999), red LEDs with leading zero blanking
Upper Display: 15 mm (0.60") high
Lower Display: 12 mm (0.46") high
Display Intensity: 8 intensity levels
Display Update Rate: 5/second (200 ms)
Overrange: Display flashes 999999
Underrange: Display flashes -99999
Display Assignment: The upper and lower displays may be assigned to PV1, PV2, PCT (percent), max/min, alternate max and min, set points, units (lower display only), or Modbus b
Front Panel: NEMA 4X (IP65)
Programming Methods: 4 front panel buttons, digital bs, PC and software, Modbus registers, or cloning using copy function
Noise Filter: Programmable from 2 to 199 (0 will disable filter)
Filter Bypass: Programmable from 0.1 to 99.9% of calibrated span
Recalibration: Calibrated at the factory. Recalibration is recommended at least every 12 months
Max/Min Display: Max (peak)/ min (valley) readings reached by the process are stored until reset by the user or until power to the meter is cycled
Password: 3 programmable passwords restrict modification of programmed settings; Pass 1: Allows use of function keys and digital bs; Pass 2: Allows use of function keys, digital bs and editing set/reset points; Pass 3: Restricts all programming, function keys, and digital bs
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost
Power Options: 85 to 265 Vac 50/60 Hz, 90 to 265 Vdc, 20 W max, or jumper selectable 12/24 Vdc ±10%, 15 W max
Fuse (External, Required): UL recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Isolated Transmitter Power Supply: 24 Vdc ±5% @ 200 mA max (standard), (12/24 Vdc powered models rated @ 100 mA max); 5 or 10 Vdc @ 50 mA max, selectable with internal jumper J4
Normal Mode Rejection: Greater than 60 dB at 50/60 Hz
Isolation: 4 kV b/output-to-power line; 500 V b-to-output or output-to-P+ supply
Overvoltage Category: Installation overvoltage category II; local level with smaller transient overvoltages than installation overvoltage category III
Operating Temperature Range: -40 to 65°C (-40 to 149°F)
Storage Temperature Range: -40 to 85°C (-40 to 185°F)
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminal blocks accept 12 to 22 AWG wire, RJ45 for external relays, digital I/O, and serial communication adaptors
Enclosure: 1/8 DIN, high impact plastic, UL 94V-0, color: black
Mounting: 1/8 DIN panel cutout required: 92 x 45 mm (3.622 x 1.772"); two panel mounting bracket assemblies are provided
Tightening Torque: Screw terminal connectors: 5 lb-in (0.56 Nm)
Overall Dimensions: 119 W x 62 H x 143 mm D (4.68 x 2.45 x 5.64")
Weight: 269 g (9.5 oz)
注釋: Comes complete with 2 side mounting brackets and operator’s manual.
產(chǎn)品型號說明
(1)
DP6000 -
選項描述
(1) Output
選擇
6R0 代表 Process panel meter
6R2 代表 Process panel meter with 2 relays
6R3 代表 Process panel meter with 4 to 20 mA output
6R4 代表 Process panel meter with 4 relays
6R5 代表 Process panel meter with 2 relays and 4 to 20 mA output
6R7 代表 Process panel meter with 4 relays and 4 to 20 mA output
7R0 代表 Process panel meter
7R2 代表 Process panel meter with 2 relays
7R3 代表 Process panel meter with 4 to 20 mA output
6H0 代表 Process panel meter
6H2 代表 Process panel meter with 2 relays
6H3 代表 Process panel meter with 4 to 20 mA output
7H0 代表 Process panel meter
7H2 代表 Process panel meter with 2 relays
7H3 代表 Process panel meter with 4 to 20 mA output